Mass Flowmeters >
LZYN  |  LK
 LK
LKS Series Coriolis Mass Flow Sensor
  • Flow range 3 to 60 Tons/Hour
  • Max working pressure up to 4MPa
  • Temperature range -50 to +200℃
  • 316L stainless steel tubes
  • Mass flow accuracy ±0.15% of flowrate ± Error of Zero (At zero instability)
  • Temperature accuracy ±1℃
  • Density accuracy ±0.002g/cm3
  • Nine-wire cabling for remote type

Application Image

LKA Series Four-wire Coriolis Mass Flow Sensor
  • Max working pressure up to 4MPa
  • Temperature range -50 to +200℃
  • 316L stainless steel tubes
  • Mass flow accuracy ±0.15% of flowrate ± Error of Zero (At zero instability)
  • Temperature accuracy ±1℃
  • Density accuracy: ±0.002g/cm3
  • Four-wire cabling for remote type
  • Intelligent core processor


LB112 Series Transmitter
  • Power supply 240VAC±10% or 24VDC±10%
  • Ambient temperature: -10 to +50℃
  • Chinese & English Language
  • 4-20mA current output & 0-10KHz scaled pulse output
  • Two contact inputs are external powered (TTL signal): The ground terminal of each contact input is the ground of 24VDC of the convertor
  • The contact output is the collector of the transistor open with galvanic isolation
  • LCD display Temperature, Density, Mass flowrate and Mass flow
  • Display accuracy ±0.05% (Fs) & ±0.01% (Fs)
  • Zeroing, Reset total flow, Total flow pause, and Zeroing warn
 Catalog Download
 Request a Quote
LK Series Coriolis Mass Flowmeters
  • Model                  LK-X, LK-XXX and LK-XXXX
  • Measured parameter        Mass flow, Density, Temperature and Volume flow
  • Fluid                                  liquids, gases or slurries
  • Sensor                              LK015 to LK150
  • Normal Diameter                DN15, DN25, DN32, DN40, DN50, DN80, DN100 &  DN150
  • Measurement range           0-3, 0-7, 0-21, 0-38, 0-60, 0-180, 0-300 & 0-600 (Tons/Hour)
  • Mass accuracy                   ±0.15% of flowrate ± EO
  • Temperature accuracy    ±1℃
  • Density accuracy                ±0.002g/cm3
  • Piping Connection        Flanged
  • Max working pressure       4.0MPa
  • Working temperature         -50℃ to +200℃
  • Housing:                           304 stainless steel
  • Housing protection            IP66
  • Measuring tube                  316L stainless steel
  • Converter installation         Wall mount, Rack mount & Field mount
  • Current output                   4-20mA
  • Frequency output                     0-10KHz
  • Power supply                     240VAC±10% or 24VDC±10%
  • Explosion proof                 ExibⅡBT4    ExdⅡBT4
  • Flowmeter installation        Remote or Integral
  • Communication protocol    RS485

Flowrate & Sensor size

Model

Nominal Diameter

Flow Range

Mass Accuracy

EO(zero instability)   

LK-15

DN15

0-3 t/h

±0.15% of flowrate

±0.0004 t/h

LK-25

DN25

0-7 t/h

±0.15% of flowrate

±0.0009 t/h

LK-32

DN32

0-21 t/h

±0.15% of flowrate

±0.0026 t/h

LK-40

DN40

0-38 t/h

±0.15% of flowrate

±0.0047 t/h

LK-50

DN50

0-60 t/h

±0.15% of flowrate

±0.0091 t/h