DMTFF Flanged Series Ultrasonic Flowmeter
- Employing transit-time ultrasonic technologies for accurate liquid measurement
- Signal quick tracking and self-adapting technologies allow system to adapt to different pipe automatically
- Flanged connection makes the meter long-term reliability and stability
- Suitable for commercial & consumable water measurement
- Monitoring and detecting water leakage for the pipe system
- Standard can be ANSI, JIS, DIN, GB and others
Specification:
|
Transmitter
|
Power Supply
|
(Std) 10-28 VDC@ 2.5VA max; 115/230VAC 50/60Hz
±15%@5VA max. Solar energy
|
|
Velocity
|
0-±40 f/s (0-±12m/s), bi-directional
|
|
Display
|
4 linexl6 English letters LCD back lit, can display total flow, flow rate, velocity and meter run status etc.
|
|
Units
Rate
Totalizer
|
User Configured (English and Metric); Rate and Velocity Display;
(FWD, NET, REV or BATCH) gallons, ft3, barrels, Ibs, liters, m3, kg
|
|
Output
|
4-20mA, Pulse, Relay, RS232C or R5485, options: up to 8 GB Data logger, Hart +(4,-20mA), Modbus
|
|
Accuracy
|
±1.0% of reading at rates >0.5 m/s
|
|
±0.005 m/s of reading at rates<0.5 m/s
|
|
Sensitivity
|
Flowrate: 0.001f/s (0.0003m/s)
|
|
Repeatability
|
0.2% of reading
|
|
Security
|
Keypad lockout, access code enable
|
|
Dimensions
|
Std.: 242*190*115; Weight: <2.5kg
|
|
Exp: 255*220*110; Weight: <5.0kg
|
|
Transducer
|
Liquid Types
Supported
|
Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration
|
|
Suited Liquid Temperature
|
Std. Temp. Transducer: -40-121℃
High Temp. Transducer: -40-150℃
|
|
Cable Length
|
Std: 20 feet (6m); Opt: Maximum: 990feet (300m)
|
|
Pipe Size
|
DN65-DN3000; select S type flange transducers if pipe<DN65
|
Application:
- Water supply and drainage water, including hot water, sewage (with less than 5% suspended solids) and sea water
- Process liquids, including liquors, beverage, olive oil and milk
- Oil, including lubricating oil, gasoline, kerosene and diesel oil
- Metallurgy, laboratory, food and medicine
- On-the-spot check-up, pipeline leak detection & judgment
Features:
- Advanced Digital Signal Processing (DSP) technology and the MultiBeam transducer technology
- Digital Cross-correlation (DCC) technology
- Non-invasive flow system allowing solids to pass through the pipe with no effect on meter
- No Y-strainers or filtering devices needed
- No-contacting sensor design making no fouling and free maintenance
- Sensors suitable for different pipe materials with wide pipe diameters
- User-friendly menu selections making DMTFF easy operations
- User-configurable in English, metric and other universal engineering units
- Event data logger available in searching the event of totalizer
- Parallel operation of positive, negative and net flow totalizers available
- The flow rate, or total pulse output and frequency output available via open collector
|