DMTFP Portable Series Ultrasonic Flowmeter
- DMTFP employs transit-time technologies for accurate liquid measurement
- Signal quality tracking and self-adapting technologies allow system to adapt to different pipe automatically
- Clamp-on design makes the transducer installation simple and no special skills or tools required
- Portable compact design for transmitter is easy for operation
Specification:
|
Transmitter
|
Power Supply
|
Internal 7.2AH re-chargeable battery. When fully charged, it can run 42 hours @20˚C. Charge power source: 240±15%VAC or solar energy
|
|
Velocity
|
0 – ±40 ft/s (0 –±12m/s), bi-directional
|
|
Display
|
4 linexl6 English letters LCD back lit, can display total flow, flow rate, velocity and meter running status etc.
|
|
Units
Rate
Totalizer
|
User Configured (English and Metric);
Rate and Velocity Display;
(FWD, NET, REV or BATCH) gallons, ft3, barrels, Ibs, liters, m3,kg
|
|
Output
|
4,-20mA, Pulse, Relay, RS232C or RS485, options: up to 8GB Data logger
|
|
Accuracy
|
±1.0%-2.0% of reading at rates >0.5 m/s
|
|
±0.003 m/s of reading at rates<0.5 m/s
|
|
Sensitivity
|
Flowrate: 0.001ft/s (0.0003m/s)
|
|
Repeatability
|
0.2% of reading
|
|
Security
|
Keypad lockout, access code enable
|
|
Transducer
|
Liquid Types
Supported
|
Virtually most any liquid containing less than 2% total suspended solids (TSS) or aeration
|
|
Suited Liquid Temperature
|
Std. Temp. Transducer: -40-121℃
High Temp. Transducer: -40-250℃
|
|
Dimensions &
Weight
|
S: Size: 42*25*25; Weight: <0.3kg
M: Size: 60*43*43; Weight: <0.6kg
L: Size: 80*53*53; Weight: <1.0kg
|
|
Pipe Size
|
Std M transducer: 40-1000mm
L transducer: 1000-4570mm
S transducer: 12-50mm
K-mode round: 12-50mm
|
|
Accessories
|
Couplant
|
Dow Corning 111 or 732 (112 for high temp.)
|
|
Elastic Belts
|
2 bundles
|
|
Battery Charger
|
1 Piece
|
|
Data Logger &
Software
|
Optional 512M to 8GB SD card
Windows-based Software Utilities, data logging, data report, data curve and analysis.
|
Application:
- Water supply and drainage water, including hot water, sewage (with less than 5% suspended solids) and sea water
- Process liquids, including liquors, beverage, olive oil and milk
- Oil, including lubricating oil, gasoline, kerosene and diesel oil
- Metallurgy, laboratory, food and medicine
- On-the-spot check-up, pipeline leak detection & judgment
Features:
- Advanced Digital Signal Processing (DSP) technology and the MultiBeam transducer technology
- Digital Cross-correlation (DCC) technology
- Non-invasive flow system allowing solids to pass through the pipe with no effect on meter
- No Y-strainers or filtering devices needed
- No-contacting sensor design making no fouling and free maintenance
- Sensors suitable for different pipe materials with wide pipe diameters
- Easy and cost-saving installation by clamping transducers on the outside of existing piping systems
- User-friendly menu selections making DMTP easy operations
- User-configurable in English, metric and other universal engineering units
- Event data logger available in searching the event of totalizer
- Parallel operation of positive, negative and net flow totalizers available
- The flow rate, or total pulse output and frequency output available via open collector
|